Summary

PR20220000886
Residential 1 or 2 Family Home
Finalled
New
Residential New Construction
08/09/2022
09/16/2022
02/28/2024
09/05/2023

Locations

Permits

Permit Number: PR20220000886

Building
Finalled

Permit Number: PR20220000886

Mechanical
Finalled

Permit Number: PR20220000886

Plumbing
Finalled

Permit Number: PR20220000886

Septic
Finalled

Reviews

Review Type Outcome Est. Review Start Date Completed
External Agencies Review Approved 09/16/2022 09/15/2022
Janelle Swanson   Send Email
Miscellaneous
Outstanding
09/08/2022


1) Paperwork missing: a. Combustion air worksheet (attached) b. Makeup air worksheet (attached) 2) Hvac load calcs revisions needed: a. The hvac load calcs should be combined as it is only one heating and cooling system not separate systems for the house and “apartment” above the garage. b. Summer indoor temp must be a minimum of 75 degrees. Calcs currently at 69 degrees. c. Winter outdoor temp must be set at -15 degrees. Calcs currently set at -4 degrees. 3) Energy certificate info needed: a. Heating system is oversized more than 40%. Once hvac load calcs are recalculated, energy certificate must be updated with the appropriately sized unit. b. Cooling system is undersized. Once hvac load calcs are recalculated, energy certificate must be updated with the appropriately sized unit. c. Missing heat loss, heat gain, and cooling load. d. Missing seer/eer value of cooling system. e. Mechanical ventilation system for a house of 5,933 sq ft and 5 bedrooms requires a total cfm of 210 and continuous cfm of 105. 4) Plans missing/need: a. Engineering required for steel beam over 16’ patio door to screen porch. b. Specs required for 8x8 cedar beam supporting front porch ridge beam. c. Engineering required for the back basement foundation wall. This foundation wall is not laterally supported at the top as the trusses bear on an interior wall in front of the foundation wall as shown in cross sections 1/7, 1/8, and 1/9 on pages 7, 8, and 9. There is no bearing on top of the foundation wall nor connected per code or the engineered foundation guide therefore, this wall requires an engineered design. d. 8’ patio door to rear porch requires a 3”x11.25” minimum header to comply with the engineered wall bracing plan e. Both cased openings on right side kitchen wall require a (2)2x12 minimum header to comply with the engineered wall bracing plan f. Cross section 1/9 shows a 14’ tall wall at the front of the kitchen area. The engineered wall bracing is based on the 2020 MSBC per the described scope and there is no specific consideration spelled out by the engineer for the braced wall panel located on this tall wall. The building code does not allow wall bracing on walls greater than 12’ in height so this must be addressed by the engineer and added to the engineered wall bracing plan. Regards, Nicolas Qualle Code Official MN CBO#: BO002752 MNSPECT, LLC., A SAFEbuilt Company Helping You Comply With The Code 235 First St. W. Waconia, MN 55367 Office: 952-442-7520 www.mnspect.com
Planning Department Review Approved 09/14/2022 09/13/2022
Nathan Hall   Send Email
Miscellaneous
Outstanding
09/08/2022


Please apply for the attached Accessory Dwelling Unit with the Zoning Department.
Building Review Not Required 09/14/2022 09/08/2022
Janelle Swanson   Send Email
Miscellaneous
Outstanding
09/08/2022


See External Review for corrections
Environmental Health Review Approved 08/16/2022 08/19/2022
Jesse Krzenski   Send Email
Fencing/Staking
Resolved
08/19/2022


Both the primary and alternate soil dispersal areas shall be fenced prior to applying for a permit to construct an SSTS. The fence shall consist of four-foot high orange construction fence, wooden snow fence, or two strands of weatherproof high-visibility roping attached to posts placed no more than 20 feet apart with either high visibility ribbon at least one-half inch wide tied to the rope no more than 6 feet apart or signs no smaller than 16 inches by 20 inches no more than 20 feet apart, that clearly identify the soil dispersal area and prohibit trespass. The fencing or roping and signs shall be clearly visible at least two feet above surrounding vegetation or snow. The choice between fencing and roping with signs shall be at the discretion of the designer and property owner and should take into consideration any risk such barrier may present. The stakes shall be clearly visible at least two feet above surrounding vegetation or snow and the stake labeling shall be legible.
Building Review Failed 08/16/2022 08/19/2022
Jeremy Schussler   Send Email
Miscellaneous
Carry Forward
09/08/2022


See External Review for corrections
External Agencies Review Failed 08/18/2022 08/19/2022
Jeremy Schussler   Send Email
Miscellaneous
Carry Forward
09/08/2022


1) Paperwork missing: a. Combustion air worksheet (attached) b. Makeup air worksheet (attached) 2) Hvac load calcs revisions needed: a. The hvac load calcs should be combined as it is only one heating and cooling system not separate systems for the house and “apartment” above the garage. b. Summer indoor temp must be a minimum of 75 degrees. Calcs currently at 69 degrees. c. Winter outdoor temp must be set at -15 degrees. Calcs currently set at -4 degrees. 3) Energy certificate info needed: a. Heating system is oversized more than 40%. Once hvac load calcs are recalculated, energy certificate must be updated with the appropriately sized unit. b. Cooling system is undersized. Once hvac load calcs are recalculated, energy certificate must be updated with the appropriately sized unit. c. Missing heat loss, heat gain, and cooling load. d. Missing seer/eer value of cooling system. e. Mechanical ventilation system for a house of 5,933 sq ft and 5 bedrooms requires a total cfm of 210 and continuous cfm of 105. 4) Plans missing/need: a. Engineering required for steel beam over 16’ patio door to screen porch. b. Specs required for 8x8 cedar beam supporting front porch ridge beam. c. Engineering required for the back basement foundation wall. This foundation wall is not laterally supported at the top as the trusses bear on an interior wall in front of the foundation wall as shown in cross sections 1/7, 1/8, and 1/9 on pages 7, 8, and 9. There is no bearing on top of the foundation wall nor connected per code or the engineered foundation guide therefore, this wall requires an engineered design. d. 8’ patio door to rear porch requires a 3”x11.25” minimum header to comply with the engineered wall bracing plan e. Both cased openings on right side kitchen wall require a (2)2x12 minimum header to comply with the engineered wall bracing plan f. Cross section 1/9 shows a 14’ tall wall at the front of the kitchen area. The engineered wall bracing is based on the 2020 MSBC per the described scope and there is no specific consideration spelled out by the engineer for the braced wall panel located on this tall wall. The building code does not allow wall bracing on walls greater than 12’ in height so this must be addressed by the engineer and added to the engineered wall bracing plan. Regards, Nicolas Qualle Code Official MN CBO#: BO002752 MNSPECT, LLC., A SAFEbuilt Company Helping You Comply With The Code 235 First St. W. Waconia, MN 55367 Office: 952-442-7520 www.mnspect.com
Planning Department Review Failed 08/16/2022 08/18/2022
Nathan Hall   Send Email
Miscellaneous
Carry Forward
09/08/2022


Please apply for the attached Accessory Dwelling Unit with the Zoning Department.
Erosion Control Plan Review Approved 08/16/2022 08/11/2022
Collin Schoenecker   Send Email
Erosion Control Field Review Not Required 08/16/2022 08/11/2022
Collin Schoenecker   Send Email

Fees

Paid Fees Amount Paid Owing Date Paid
Building Permit Fee (NEW HOME) $8,031.65 $8,031.65 Paid 09/15/2022
Building Permit State Surcharge $624.00 $624.00 Paid 09/15/2022
Plan Check Fee (Building) $5,220.57 $5,220.57 Paid 09/15/2022
Mechanical Permit Fee - Fireplace or Wood Stove $76.00 $76.00 Paid 09/15/2022
Mechanical Permit Fee/New System $171.00 $171.00 Paid 09/15/2022
Plumbing Permit Fee/New System $171.00 $171.00 Paid 09/15/2022
Septic New for SSTS $775.00 $775.00 Paid 09/15/2022
ESC Review Fee for Accessory Structures $130.00 $130.00 Paid 09/15/2022
ESC Escrow $1,000.00 $1,000.00 Paid 09/15/2022
911 Address Marker Fees/New Home $110.00 $110.00 Paid 09/15/2022
Septic Inspection/Reinspection $110.00 $110.00 Paid 09/15/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Septic Drainfield Installation Passed 09/27/2022
Septic Tank Installation Passed 09/28/2022
Septic Final Cover Passed 09/28/2022
Footing Passed 10/6/2022 (10:30 to 11:00) 10/6/2022 (AM) 10/06/2022
Poured Wall Forms Passed 10/19/2022 (8:30 to 9:00) 10/19/2022 (AM) 10/19/2022
Foundation Passed 10/25/2022 (3:00 to 3:30) 10/25/2022 (PM) 10/25/2022
Plumbing Rough-in Partial Pass 12/20/2022 (8:30 to 9:00) 12/20/2022 (AM) 12/20/2022
Miscellaneous
Carry Forward
12/20/2022
Below grade DWV appears ok. Air test passed.

Miscellaneous
Carry Forward
12/20/2022
Above grade RI not ready for inspection.

Radon Above Grade Rough In Failed 12/20/2022 (8:30 to 9:00) 12/20/2022 (AM) 12/20/2022
Miscellaneous
Carry Forward
12/20/2022
Not ready for inspection yet.

Radon/Vapor Barrier Under Slab Passed 12/21/2022 (3:00 to 3:30) 12/21/2022 (PM) 12/21/2022
Plumbing Rough-in Partial Pass 1/9/2023 (1:30 to 2:00) 1/9/2023 (PM) 01/09/2023
Miscellaneous
Carry Forward
01/09/2023
Below grade DWV appears ok. Air test passed.

Miscellaneous
Carry Forward
01/09/2023
Above grade RI not ready for inspection.

Radon Above Grade Rough In Failed 1/10/2023 (10:00 to 10:30) 1/10/2023 (AM) 01/10/2023
Miscellaneous
Carry Forward
01/10/2023
Not ready for inspection yet.

Radon/Vapor Barrier Under Slab Passed 1/10/2023 (10:00 to 10:30) 1/10/2023 (AM) 01/10/2023
Framing/Weather Barrier/Roof Partial Pass 2/8/2023 (1:00 to 1:30) 2/8/2023 (PM) 02/08/2023
Miscellaneous
Carry Forward
02/08/2023
House wrap and shingles ok - Metal roofs not installed yet. Framing not inspected. Partial pass

Miscellaneous
Carry Forward
02/08/2023
Mechanical exhaust caps not installed on roof yet.

Mechanical Rough-in Passed 2/8/2023 (1:00 to 1:30) 2/8/2023 (PM) 02/08/2023
Radon Above Grade Rough In Passed 2/17/2023 (9:30 to 10:00) 2/17/2023 (AM) 02/17/2023
Miscellaneous
Outstanding
01/10/2023
Not ready for inspection yet.

Plumbing Rough-in Partial Pass 2/17/2023 (9:30 to 10:00) 2/17/2023 (AM) 02/17/2023
Miscellaneous
Resolved
02/17/2023
Below grade DWV appears ok. Air test passed.

Miscellaneous
Resolved
02/17/2023
Above grade RI not ready for inspection.

Miscellaneous
Carry Forward
02/17/2023
Air test needed for supply.

Miscellaneous
Carry Forward
02/17/2023
Above ground DWV is good.

Framing/Weather Barrier/Roof Partial Pass 2/21/2023 (9:00 to 9:30) 2/21/2023 (AM) 02/21/2023
Miscellaneous
Resolved
02/21/2023
House wrap and shingles ok - Metal roofs not installed yet. Framing not inspected. Partial pass

Miscellaneous
Resolved
02/21/2023
Mechanical exhaust caps not installed on roof yet.

Miscellaneous
Carry Forward
02/21/2023
Metal roofs not installed yet.

Miscellaneous
Inspector Comment
02/21/2023
Okay to insulate.

Insulation Partial Pass 3/3/2023 (8:30 to 9:00) 3/3/2023 (AM) 03/03/2023
Miscellaneous
Carry Forward
03/03/2023
Open voids in the draft stopping.

Miscellaneous
Carry Forward
03/03/2023
Garage not insulated yet.

Miscellaneous
Carry Forward
03/03/2023
Main floor and loft living space insulation/vapor is good. Partial Pass

Fireplace Rough-In Partial Pass 3/3/2023 (8:00 to 8:30) 3/3/2023 (AM) 03/03/2023
Miscellaneous
Resolved
04/27/2023
Main floor gas FP's are good. The FP in the porch is not installed yet.

Miscellaneous
Resolved
04/27/2023
Lower level wood FP on separate permit.

Gasline Failed 3/3/2023 (8:00 to 8:30) 3/3/2023 (AM) 03/03/2023
Miscellaneous
Carry Forward
03/03/2023
Pressure gauges were at zero at the time of the inspection.

Insulation Partial Pass 3/6/2023 (1:00 to 1:30) 3/6/2023 (PM) 03/06/2023
Miscellaneous
Carry Forward
03/06/2023
Open void in the draft stopping above plenum.

Miscellaneous
Resolved
03/06/2023
Garage not insulated yet.

Miscellaneous
Resolved
03/06/2023
Main floor and loft living space insulation/vapor is good. Partial Pass

Gasline Failed 03/06/2023
Miscellaneous
Carry Forward
03/06/2023
Pressure gauges were at zero at the time of the inspection.

Gasline Passed 3/8/2023 (2:00 to 2:30) 3/8/2023 (PM) 03/09/2023
Miscellaneous
Outstanding
03/06/2023
Pressure gauges were at zero at the time of the inspection.

Insulation Passed 03/14/2023
Miscellaneous
Resolved
03/14/2023
Open void in the draft stopping above plenum.

Plumbing Rough-in Passed 03/14/2023
Miscellaneous
Resolved
03/14/2023
Air test needed for supply.

Miscellaneous
Resolved
03/14/2023
Above ground DWV is good.

Interior Wall Bracing Panels Passed 3/14/2023 (1:00 to 1:30) 3/14/2023 (PM) 03/14/2023
Fireplace Rough-In Passed 4/27/2023 (3:00 to 3:30) 4/27/2023 (PM) 04/27/2023
Miscellaneous
Resolved
04/27/2023
Main floor gas FP's are good. The FP in the porch is not installed yet.

Miscellaneous
Resolved
04/27/2023
Lower level wood FP on separate permit.

Lath Not Required 7/19/2023 (1:30 to 2:00) 7/19/2023 (PM) 07/20/2023
Plumbing Final Passed 7/19/2023 (2:00 to 2:30) 7/19/2023 (PM) 07/20/2023
Mechanical Final Passed 7/19/2023 (1:30 to 2:00) 7/19/2023 (PM) 07/20/2023
Radon Final Passed 7/19/2023 (2:30 to 3:00) 7/19/2023 (PM) 07/20/2023
Framing/Weather Barrier/Roof Passed 7/19/2023 (2:00 to 2:30) 7/19/2023 (PM) 07/20/2023
Miscellaneous
Resolved
07/20/2023
Metal roofs not installed yet.

Final Failed 7/24/2023 (3:00 to 3:30) 7/24/2023 (PM) 07/24/2023
Miscellaneous
Carry Forward
07/24/2023
Siding not completed on rear of home adjacent to pool

Electrical Final inspection
Carry Forward
07/24/2023
Electrical Final Inspection required

Miscellaneous
Carry Forward
07/24/2023
Fire blocking required on basement mechanical room a interior wall where it meets the floor joists

Miscellaneous
Carry Forward
07/24/2023
Foundation insulation is exposed by pool

Insulation card
Carry Forward
07/24/2023
Insulation certificate MEC 1322.0103

Miscellaneous
Carry Forward
07/24/2023
Submit blower door test, ok to email to thussong@co.Scott.mn.us

Final Partial Pass 07/27/2023
Miscellaneous
Carry Forward
07/27/2023
Siding not completed on rear of home adjacent to pool

Electrical Final inspection
Carry Forward
07/27/2023
Electrical Final Inspection required

Miscellaneous
Resolved
07/27/2023
Fire blocking required on basement mechanical room a interior wall where it meets the floor joists

Miscellaneous
Carry Forward
07/27/2023
Foundation insulation is exposed by pool

Insulation card
Resolved
07/27/2023
Insulation certificate MEC 1322.0103

Miscellaneous
Resolved
07/27/2023
Submit blower door test, ok to email to thussong@co.Scott.mn.us

Final Partial Pass 07/27/2023
Miscellaneous
Carry Forward
07/27/2023
Siding not completed on rear of home adjacent to pool

Electrical Final inspection
Resolved
07/27/2023
Electrical Final Inspection required

Miscellaneous
Carry Forward
07/27/2023
Foundation insulation is exposed by pool

Final Passed 9/1/2023 (3:00 to 3:30) 9/1/2023 (PM) 09/01/2023
Miscellaneous
Resolved
09/01/2023
Siding not completed on rear of home adjacent to pool

Miscellaneous
Resolved
09/01/2023
Foundation insulation is exposed by pool

Erosion Control Final Passed 09/28/2023