Search button

Scott County, MN Web Portal

Permit Application Status

PR20220000672




Note: You can collapse and expand individual sections by clicking the header of the section you wish to collapse/expand.

Summary

PR20220000672
Residential 1 or 2 Family Home
Finalled
New
New home, walk-out Rambler with garage roughly 5,000 sq ft. Custom Home.
07/05/2022
08/12/2022
12/27/2023
06/30/2023

Locations

Permits

Permit Number: PR20220000672

Building
Finalled

Permit Number: PR20220000672

Mechanical
Finalled

Permit Number: PR20220000672

Plumbing
Finalled

Permit Number: PR20220000672

Septic
Finalled

Reviews

Review Type Outcome Est. Review Start Date Completed
Building Review Approved 08/12/2022 08/11/2022
Thomas Hussong   Send Email
Miscellaneous
Resolved
08/11/2022


Provide truss specs and layout for floor Joists and roof trusses, revise and resubmit
Miscellaneous
Resolved
08/11/2022


Provide Header and Beam sizes, revise and resubmit
Erosion Control Plan Review Approved 08/12/2022 08/11/2022
Collin Schoenecker   Send Email
Miscellaneous
Outstanding
08/08/2022


Erosion Control Forms are missing, two plans were uploaded.
Environmental Health Review Approved 08/12/2022 08/08/2022
Dave Guenther   Send Email
Environmental Health Review Failed 07/29/2022 08/05/2022
Dave Guenther   Send Email
Building Review Failed 07/29/2022 07/26/2022
Thomas Hussong   Send Email
Miscellaneous
Carry Forward
08/08/2022


Provide truss specs and layout for floor Joists and roof trusses, revise and resubmit
Miscellaneous
Carry Forward
08/08/2022


Provide Header and Beam sizes, revise and resubmit
Planning Department Review Approved 07/29/2022 07/26/2022
Nathan Hall   Send Email
Erosion Control Plan Review Failed 07/29/2022 07/25/2022
Collin Schoenecker   Send Email
Miscellaneous
Carry Forward
08/08/2022


Erosion Control Forms are missing, two plans were uploaded.
Erosion Control Field Review Not Required 07/29/2022 07/25/2022
Collin Schoenecker   Send Email

Fees

Paid Fees Amount Paid Owing Date Paid
Building Permit Fee $4,546.65 $4,546.65 Paid 08/12/2022
Building Permit State Surcharge $310.00 $310.00 Paid 08/12/2022
Plan Check Fee (Building) $2,955.32 $2,955.32 Paid 08/12/2022
Mechanical Permit Fee - Fireplace or Wood Stove $76.00 $76.00 Paid 08/12/2022
Mechanical Permit Fee/New System $171.00 $171.00 Paid 08/12/2022
Plumbing Permit Fee/New System $171.00 $171.00 Paid 08/12/2022
Septic New for SSTS $775.00 $775.00 Paid 08/12/2022
911 Address Marker Fees/New Home $110.00 $110.00 Paid 08/12/2022
ESC Review Fee for Accessory Structures $130.00 $130.00 Paid 08/12/2022
ESC Escrow $1,000.00 $1,000.00 Paid 08/12/2022
Outstanding Fees Amount Paid Owing Date Paid
No outstanding fees.


$0.00

Inspections

Inspection Outcome Requested Scheduled Date Inspected
Footing Passed 8/31/2022 (10:00 to 10:30) 8/31/2022 (AM) 08/31/2022
Poured Wall Forms Passed 9/12/2022 (2:00 to 2:30) 9/12/2022 (PM) 09/12/2022
Foundation Passed 9/16/2022 (10:30 to 11:00) 9/16/2022 (AM) 09/16/2022
Septic Drainfield Installation Passed 09/21/2022
Septic Tank Installation Passed 09/21/2022
Plumbing Rough-in Partial Pass 9/23/2022 (2:30 to 3:00) 9/23/2022 (PM) 09/23/2022
Miscellaneous
Carry Forward
09/23/2022
Underground dwv inspected and passed.

Radon/Vapor Barrier Under Slab Passed 9/26/2022 (9:00 to 9:30) 9/26/2022 (AM) 09/26/2022
Septic Final Cover Passed 10/11/2022
Radon Above Grade Rough In Passed 12/2/2022 (2:00 to 2:30) 12/2/2022 (PM) 12/02/2022
Plumbing Rough-in Passed 12/2/2022 (2:00 to 2:30) 12/2/2022 (PM) 12/02/2022
Miscellaneous
Resolved
12/02/2022
Underground dwv inspected and passed.

Miscellaneous
Inspector Comment
12/02/2022
All Plumbing rough in appears OK

Mechanical Rough-in Passed 12/6/2022 (2:00 to 2:30) 12/6/2022 (PM) 12/06/2022
Gasline Passed 12/6/2022 (2:00 to 2:30) 12/6/2022 (PM) 12/06/2022
Fireplace Rough-In Not Required 12/6/2022 (2:00 to 2:30) 12/6/2022 (PM) 12/06/2022
Miscellaneous
Inspector Comment
12/06/2022
The fireplace is set up for gas but is going to be an electric fireplace for now.

Framing/Weather Barrier/Roof Partial Pass 12/6/2022 (2:30 to 3:00) 12/6/2022 (PM) 12/06/2022
Miscellaneous
Carry Forward
12/06/2022
House wrap missing at the front gable end - partial pass.

Framing/Weather Barrier/Roof Partial Pass 12/16/2022 (1:30 to 2:00) 12/16/2022 (PM) 12/16/2022
Miscellaneous
Carry Forward
12/16/2022
House wrap missing at the front gable end - partial pass.

Miscellaneous
Carry Forward
12/16/2022
House wrap is not complete on front gables. When complete send images to buildinginspections@co.scott.mn.us. Reference permit number PR22-0672

Insulation Partial Pass 12/16/2022 (1:30 to 2:00) 12/16/2022 (PM) 12/16/2022
Miscellaneous
Carry Forward
12/16/2022
MRC R302.11 fire blocking is required in all concealed spaces. Install blocking on ceiling of fireplace enclosure. Do not drywall fire place until re inspection.

Miscellaneous
Carry Forward
12/16/2022
All lower level soffit/framed ceiling around duct shall be complete with appropriate fire blocking in concealed spaces. Reinspect when complete.

Miscellaneous
Inspector Comment
12/16/2022
Except the two above corrections the rest of the insulation has passed and OK to sheetrock. Reinspect the two correction areas prior to covering.

Framing/Weather Barrier/Roof Passed 2/17/2023 (1:00 to 1:30) 2/17/2023 (PM) 02/17/2023
Miscellaneous
Resolved
02/17/2023
House wrap missing at the front gable end - partial pass.

Miscellaneous
Resolved
02/17/2023
House wrap is not complete on front gables. When complete send images to buildinginspections@co.scott.mn.us. Reference permit number PR22-0672

Insulation Passed 2/17/2023 (1:30 to 2:00) 2/17/2023 (PM) 02/17/2023
Miscellaneous
Resolved
02/17/2023
MRC R302.11 fire blocking is required in all concealed spaces. Install blocking on ceiling of fireplace enclosure. Do not drywall fire place until re inspection.

Miscellaneous
Resolved
02/17/2023
All lower level soffit/framed ceiling around duct shall be complete with appropriate fire blocking in concealed spaces. Reinspect when complete.

Plumbing Final Partial Pass 2/17/2023 (1:00 to 1:30) 2/17/2023 (PM) 02/17/2023
Miscellaneous
Carry Forward
02/17/2023
Install trap in lower level lavatory. Finish walk-in showers. Corrections can be verified at final inspection.

Radon Final Passed 3/10/2023 (3:00 to 3:30) 3/10/2023 (PM) 03/10/2023
Plumbing Final Passed 3/10/2023 (3:00 to 3:30) 3/10/2023 (PM) 03/10/2023
Miscellaneous
Resolved
03/10/2023
Install trap in lower level lavatory. Finish walk-in showers. Corrections can be verified at final inspection.

Mechanical Final Passed 3/10/2023 (2:30 to 3:00) 3/10/2023 (PM) 03/10/2023
Final Partial Pass 3/10/2023 (3:30 to 4:00) 3/10/2023 (PM) 03/10/2023
Miscellaneous
Carry Forward
03/10/2023
A/C not connected yet.

Miscellaneous
Carry Forward
03/10/2023
Lath on front of house not completed.

Miscellaneous
Carry Forward
03/10/2023
Drainage - 6” within first 10’-0” from structure (IRC R401.3)

Lath Failed 3/10/2023 (2:30 to 3:00) 3/10/2023 (PM) 03/13/2023
Miscellaneous
Carry Forward
03/13/2023
Not ready for inspection.

Lath Passed 6/30/2023 (10:30 to 11:00) 6/30/2023 (AM) 06/30/2023
Miscellaneous
Resolved
06/30/2023
Not ready for inspection.

Final Passed 6/30/2023 (10:30 to 11:00) 6/30/2023 (AM) 06/30/2023
Miscellaneous
Resolved
06/30/2023
A/C not connected yet.

Miscellaneous
Resolved
06/30/2023
Lath on front of house not completed.

Miscellaneous
Resolved
06/30/2023
Drainage - 6” within first 10’-0” from structure (IRC R401.3)

Erosion Control Final Passed 05/28/2024
Government Websites by CivicPlus®